Print
Chemical Datasheet
ACETONITRILE |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
- 75-05-8
|
|
|
|
NIOSH Pocket Guide |
International Chem Safety Card |
Acetonitrile
|
|
NFPA 704
General Description
A colorless limpid liquid with an aromatic odor. Flash point 42掳F. Density 0.783 g / cm3. Toxic by skin absorption. Less dense than water. Vapors are denser than air.
Hazards
Reactivity Alerts
Air & Water Reactions
Highly flammable. Water soluble.
Fire Hazard
Special Hazards of Combustion Products: Toxic vapors are generated when heated
Behavior in Fire: Vapor heavier than air and may travel a considerable distance to a source of ignition and flash back. (USCG, 1999)
Health Hazard
Exposure to 160 ppm for 4 hours causes flushing of the face and a feeling of constriction in the chest; 500 ppm for brief periods is irritating to the nose and throat. Severe exposures cause irritability, skin eruptions, confusion, delirium, convulsions, paralysis, and death due to central nervous system depression. (USCG, 1999)
Reactivity Profile
ACETONITRILE decomposes when heated to produce deadly toxic hydrogen cyanide gas and oxides of nitrogen. Strongly reactive [Hawley]. May react vigorously with strong oxidizing reagents, sulfuric acid, chlorosulfonic acid, sulfur trioxide, perchlorates, nitrating reagents, and nitric acid. [Sax, 9th ed., 1996, p. 20]. Potentially explosive in contact with nitrogen-fluorine compounds (e.g., tetrafluorourea) [Fraser, G. W. et al., Chem. Comm., 1966, p. 532].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
Response Recommendations
Isolation and Evacuation
Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:
CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient. CAUTION: For fire involving UN1170, UN1987 or UN3475, alcohol-resistant foam should be used. CAUTION: Ethanol (UN1170) can burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).
SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.
LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.
FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 127 [Flammable Liquids (Water-Miscible)]:
ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.
LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Acetonitrile:
Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.
Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.
Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.
Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100掳F).
Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.
Provide: QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem庐 Suit Fabrics
Normalized Breakthrough Times (in Minutes)
Chemical |
CAS Number |
State |
QS |
QC |
SL |
C3 |
TF |
TP |
RC |
TK |
RF |
Acetonitrile |
75-05-8 |
Liquid |
imm |
imm |
60 |
imm |
131 |
>480 |
>480 |
>480 |
>480 |
Cyanomethane |
75-05-8 |
Liquid |
imm |
imm |
60 |
imm |
131 |
>480 |
>480 |
>480 |
>480 |
Ethane nitrile |
75-05-8 |
Liquid |
imm |
imm |
60 |
imm |
131 |
>480 |
>480 |
>480 |
>480 |
Ethyl nitrile |
75-05-8 |
Liquid |
imm |
imm |
60 |
imm |
131 |
>480 |
>480 |
>480 |
>480 |
Methyl cyanide |
75-05-8 |
Liquid |
imm |
imm |
60 |
imm |
131 |
>480 |
>480 |
>480 |
>480 |
Special Warning from DuPont: Tychem庐 and Tyvek庐 fabrics should not be
used around heat, flames, sparks or in potentially flammable or
explosive environments. Only...
(DuPont, 2024)
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment.
INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.
INGESTION: DO NOT INDUCE VOMITING. Volatile chemicals have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)
Physical Properties
Flash Point:
42掳F
(NTP, 1992)
Lower Explosive Limit (LEL):
4.4 %
(NTP, 1992)
Upper Explosive Limit (UEL):
16 %
(NTP, 1992)
Autoignition Temperature:
975掳F
(USCG, 1999)
Melting Point:
-49掳F
(NTP, 1992)
Vapor Pressure:
73 mmHg
at 68掳F
(NTP, 1992)
Vapor Density (Relative to Air):
1.42
(NTP, 1992)
- Heavier than air; will sink
Specific Gravity:
0.787
at 68掳F
(USCG, 1999)
- Less dense than water; will float
Boiling Point:
178.9掳F
at 760 mmHg
(NTP, 1992)
Molecular Weight:
41.05
(NTP, 1992)
Water Solubility:
greater than or equal to 100 mg/mL
at 72.5掳F
(NTP, 1992)
Ionization Energy/Potential:
12.20 eV
(NIOSH, 2024)
IDLH:
137 ppm
(NIOSH, 2024)
AEGLs (Acute Exposure Guideline Levels)
Final AEGLs for Acetonitrile (75-05-8)
Exposure Period |
AEGL-1 |
AEGL-2 |
AEGL-3 |
10 minutes |
13 ppm |
80 ppm |
240 ppm |
30 minutes |
13 ppm |
80 ppm |
240 ppm |
60 minutes |
13 ppm |
50 ppm |
150 ppm |
4 hours |
13 ppm |
21 ppm |
64 ppm |
8 hours |
NR |
14 ppm |
42 ppm |
(NAC/NRC, 2024)
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
|
Acetonitrile (75-05-8)
|
13 ppm |
50 ppm |
150 ppm |
LEL = 30000 ppm |
(DOE, 2024)
Regulatory Information
EPA Consolidated List of Lists
Regulatory Name |
CAS Number/ 313 Category Code |
EPCRA 302 EHS TPQ |
EPCRA 304 EHS RQ |
CERCLA RQ |
EPCRA 313 TRI |
RCRA Code |
CAA 112(r) RMP TQ |
Acetonitrile |
75-05-8 |
|
|
5000 pounds |
313 |
U003 |
|
(EPA List of Lists, 2024)
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- ACETONITRILE
- ACETONITRILE CLUSTER
- CYANOMETHANE
- ETHANENITRILE
- ETHYL NITRILE
- METHANE, CYANO-
- METHANECARBONITRILE
- METHYL CYANIDE
- METHYL CYANIDE (MECN)
- NCI-C60822
- USAF EK-488