Print
Chemical Datasheet
TUNGSTEN HEXAFLUORIDE |
|
Chemical Identifiers
CAS Number |
UN/NA Number |
DOT Hazard Label |
USCG CHRIS Code |
- 7783-82-6
|
|
|
none
|
NIOSH Pocket Guide |
International Chem Safety Card |
none
|
none
|
NFPA 704
data unavailable
General Description
A toxic corrosive light yellow liquid or gas. Noncombustible. Used in the manufacture of other chemicals and in the manufacture of electronics.
Hazards
Reactivity Alerts
Air & Water Reactions
Decomposes in water giving hydrofluoric acid, another corrosive material.
Fire Hazard
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
Some may burn but none ignite readily. Vapors from liquefied gas are initially heavier than air and spread along ground. Some of these materials may react violently with water. Cylinders exposed to fire may vent and release toxic and/or corrosive gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. For UN1005: Anhydrous ammonia, at high concentrations in confined spaces, presents a flammability risk if a source of ignition is introduced. (ERG, 2024)
Health Hazard
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
TOXIC and/or CORROSIVE; may be fatal if inhaled, ingested or absorbed through skin. Vapors are extremely irritating and corrosive. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)
Reactivity Profile
TUNGSTEN HEXAFLUORIDE emits very toxic and irritating fumes containing metallic tungsten and tungsten fluorides when heated to decomposition. Reacts violently with tetramethoxysilane [Jacob, E., Angew. Chem., 1982, 21, p. 143].
Belongs to the Following Reactive Group(s)
- Fluoride Salts, Soluble
- Halogenating Agents
Potentially Incompatible Absorbents
Use caution: Liquids with this reactive group classification have been
known to react with the
absorbents
listed below.
- Cellulose-Based Absorbents
- Mineral-Based & Clay-Based Absorbents
- Sand
- Dirt/Earth
Response Recommendations
Isolation and Evacuation
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2196 datasheet.
FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. (ERG, 2024)
Firefighting
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
SMALL FIRE: Dry chemical or CO2.
LARGE FIRE: Water spray, fog or regular foam. If it can be done safely, move undamaged containers away from the area around the fire. Do not get water inside containers. Damaged cylinders should be handled only by specialists.
FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
Non-Fire Response
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Isolate area until gas has dispersed. (ERG, 2024)
Protective Clothing
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
DuPont Tychem速 Suit Fabrics
Normalized Breakthrough Times (in Minutes)
Chemical |
CAS Number |
State |
QS |
QC |
SL |
C3 |
TF |
TP |
RC |
TK |
RF |
Tungsten hexafluoride |
7783-82-6 |
Vapor |
|
|
|
|
|
|
>480 |
>480 |
>480 |
Special Warning from DuPont: Tychem速 and Tyvek速 fabrics should not be
used around heat, flames, sparks or in potentially flammable or
explosive environments. Only...
(DuPont, 2024)
First Aid
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
Refer to the "General First Aid" section. Specific First Aid: In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of skin contact with hydrogen fluoride, anhydrous (UN1052), if calcium gluconate gel is available, rinse 5 minutes, then apply gel. Otherwise, continue rinsing until medical treatment is available. (ERG, 2024)
Physical Properties
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight:
297.9
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.
ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.
PACs (Protective Action Criteria)
Chemical |
PAC-1 |
PAC-2 |
PAC-3 |
Tungsten hexafluoride (7783-82-6)
|
4.9 mg/m3 |
54 mg/m3 |
320 mg/m3 |
(DOE, 2024)
Regulatory Information
EPA Consolidated List of Lists
No regulatory information available.
CISA Chemical Facility Anti-Terrorism Standards (CFATS)
|
RELEASE |
THEFT |
SABOTAGE |
Chemical of Interest |
CAS Number |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Min Conc |
STQ |
Security Issue |
Tungsten hexafluoride |
7783-82-6 |
|
|
|
7.10 % |
45 pounds |
WME |
|
|
|
(CISA, 2007)
OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
Alternate Chemical Names
- HEXAFLUOROTUNGSTEN
- TUNGSTEN FLUORIDE
- TUNGSTEN FLUORIDE (WF6)
- TUNGSTEN HEXAFLUORIDE
- TUNGSTEN HEXAFLUORIDE (WF6)
- TUNGSTEN(6+) FLUORIDE